30
User Manual
IDENTIFYING SYSTEM TROUBLES
STEP DESCRIPTION
1
Perform if the POWER LED is flashing. If lit steadily, there
are no system troubles. To view trouble conditions, the
system must be disarmed. Enter the User Functions Mode
by pressing [ ] and then select View Troubles (3):
2
The keypad will beep and its LEDs will light, reflecting the
information below. After several seconds, the display will
return to normal.
FLASHING: Trouble Detected
OFF:
(normal in this mode)
OFF:
(normal in this mode)
IF ON: Fire Zone Trouble
(contact your dealer)
IF ON: Low Battery (contact dealer)
IF ON: AC Power Loss (see Note 1)
IF ON: Clock, Time & Date Not Set
(see page 19)
IF ON: Communications Trouble
(see Note 2)
3
IF ON: Bell Loop Trouble
(see Note 3)
In an 8 zone keypad there are 2 more LEDs which are only zone indicators
and not system indicators.
NOTE 1: Check that the ORBIT-6's Plug-In Transformer has not been
removed from its outlet. If intact, check that a blown fuse, a switch, or a
tripped circuit breaker has not interrupted the circuit supplying power to
the transformer.
NOTE 2: The ORBIT-6 has failed in its attempts to report an alarm or
trouble condition to the Central Station. Check that your telephone line is
functioning. Check to see if your external bell has been tampered with. If the
problem still exists contact your dealer.
NOTE 3: The ORBIT-6 has failed in its attempt to identify the Bell Loop.
It is possible for more than one trouble to be present at the same time.
If so, multiple Zone LEDs will be lit simultaneously.
Comentarios a estos manuales