Rokonet ORBiT-14 Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
Installation and Programming Manual
41
SYSTEM: TIME DEFINE (cont’d)
Quick Key Item Default Range Explanation
TIME DEFINE (cont’d)
1 1 7 Zone Test Times ---
specifies the Start Time and Zone Test Period for
Zone Testing (see page 57 for additional information)
1 1 7 1 Start Test At:
HR:00
MIN:00
00-24
00-59
1 1 7 2 Zone Test Period* 00 00-24
§§ this feature permits an automatic self-
testing routine for a group of up to 16
zones; the concept and procedures are
fully explained, beginning on page 57
§§ use the Start Test At parameter to define
the time of day (expressed in 24-hour
terms) when the test should first be
performed
§§ use the Zone Test Period parameter to
define how often (every hour to every 24
hours), after the initial test is conducted,
that each subsequent test will occur
*Not for UL Installations
INSTALLER PROG:
1)SYSTEM
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 69 70

Comentarios a estos manuales

Sin comentarios