Installation and Programming Manual
44
SYSTEM: SYSTEM CONTROL
Quick Key Item Default Explanation
SYSTEM CONTROL (cont’d)
1 2 22 Forced Keyswitch
Arming
Not for UL
Installations
YES
if YES: and keyswitch arming is performed on any partition,
any violated (not READY) zone(s) in the partition will
be automatically bypassed
the partition will be said to be “force armed”
all intact zones will be capable of producing an alarm
if NO: the partition cannot be armed through the use of the
keyswitch until all violated (not READY) zones are
secured
This parameter relates to the use of an alphanumeric pocket
pager and to the customer’s desire to be notified when
partition specific events occur. Initially, the pager’s phone
number must be programmed as a “Follow-Me” device in the
ORBIT-Pro’s User Functions
if YES: allows enhanced event information to be provided to
the numeric or alphanumeric pager, which will be
delivered and displayed once the call is made.
The following tips and examples are provided to better define
this function:
§ after entering the phone number as described above,
add one (or more) “Bs” (S + 2) to delay, as required, an
appropriate interval allowing the paging service to
answer
§ the following messages will be delivered automatically
to the pager:
DISPLAYED MEANING
1# the system (or partition) is armed
2# the system (or partition) is disarmed
3# the system (or partition) is in alarm
§ it is possible to further enhance the displayed message
by adding meaningful characters after the “B”–for
example, as a means to identify the partition being
reported
§ for example, using a “2” after the last “B”; will cause
each message to be preceded by a “2”–presumably
identifying the affected partition
CHARACTERS
ADDED AFTER “B”
IF
DISPLAYED
MEANING
1 11# Partition 1 is armed
2 21# Partition 2 is armed
3 32# Partition 3 is disarmed
8 83# Partition 3 is in alarm
1 2 23 Pager NO
if NO: a pager will be called only during an alarm condition in
the partition to which it was programmed as a “Follow-
Me” device; as such, there will be no enhancements to
the standard message being delivered