Installation and Programming Manual
64
UTILITY OUTPUT: SYSTEM (cont’d)
Quick Key Utility Output Follows Default Explanation
SYSTEM (cont’d)
5
Ground Pulse
---
§ activates when the ORBIT-Pro’s dialer must dial
out
§ rarely used, this option is typically intended for
older phone systems which require a
“Ground Start” (a momentary connection between
one side of the phone line and “earth” ground) to
obtain dial tone
§ when the Utility Output is programmed (and
properly wired) for this purpose, it will provide a
2-3 pulse needed to furnish dial tone to the dialer
§ if the Ground Pulse option is used, the “Pattern of
Operation” options, which follow, will not apply
6
Low Battery Follow
---
§ activates when the ORBIT-Pro’s rechargeable
standby battery is found to have insufficient
reserve capacity
7
AC Loss Follow
--- § activates when the source of the panel’s AC
power has been interrupted
8
Sensors Test
Not for UL
Installations
--- § relates to the ORBIT-Pro’s Zone Self-Test,
described on page 59
§ if selected, the designated Utility Output is
intended to be part of the circuit providing
switched power for the source of noise (or
vibration) used in the procedure
INSTALLER PROG:
3) UO