Installation and Programming Manual
67
UTILITY OUTPUT: ZONE
Quick Key Utility Output Follows Default Explanation
ZONE
--- § the Utility Output will follow the chosen
Zone Event and Zone Number, selected among
those listed below:
§ after making your selections, press [ENTER]
§ proceed to PATTERN of OPERATION, and
period of duration.
1
Zone Follow
---
§ activates the designated Utility Output
whenever the selected zone is tripped; select
by pressing [ENTER]
§ the tripped zone need not be armed to trigger
the Utility Output
zones 1 through “x” ---
§ select the zone for which the violation will
activate the designated Utility Output
§ next, press [ENTER] to select the desired
PATTERN OF OPERATION,
2
Alarm Follow
---
§ activates the designated Utility Output
whenever the selected zone causes an alarm;
select by pressing [ENTER]
zones 1 through “x”
§ select the zone for which an alarm condition will
activate the designated Utility Output
§ next, press [ENTER] to select the desired
PATTERN OF OPERATION,
3
Arm Follow
§ activates the designated Utility Output
whenever the selected zone is armed by the
system; select by pressing [ENTER]
zones 1 through “x”
§ select the zone, which, when armed, will
activate the designated Utility Output
§ next, press [ENTER] to select the desired
PATTERN OF OPERATION,